Error No: 00161 appears when connecting to SMARTEAM with CATIA for one user.

Error No: 00161 appears when connecting to SMARTEAM with CATIA for one user.

Error No: 00161 appears when connecting to SMARTEAM with CATIA for one user.

Error No: 00161
No objects were found for the requested view.

Resetting the User's Profile on the Foundation server resolved the issue.

-----

1. On the Foundation server, stop the SmarTeam Session Management Service

(this will automatically stop all the other SMARTEAM services and it will boot everyone out of SMARTEAM because it kills the user sessions)

2. Wait 30 seconds.

3. On the Foundation server, rename the user folder for the user having the issue:

<SmarTeam>\ConfigurationSettings\Data\User\<user>

Just rename it to <user>_old

(For Active Directory Authentication the folders will look like this: cn=<active_directory_information>)

4. Start the SmarTeam Configuration Service

(it will automatically start the SmarTeam Session Management Service)

5. Then start the other SMARTEAM services (SmarTeam Vault Service and SmarTeam Workflow Service)


    • Related Articles

    • Error No 00012 when saving a CATIA Drawing to SMARTEAM.

      Error No 00012 when saving a CATIA Drawing to SMARTEAM. Error No: 00012 Internal Error. The program was unable to complete the operation due to an internal error. Please report the following details to your System Administrator. Wrong Class Handle. ...
    • SmarTeam Internal Error appears when running Data Model Designer.

      SmarTeam Internal Error appears when running Data Model Designer. This issue can occur because of some entries in the TDM_CLASS_SATELLITES and TDM_DEF_CLASS_SATELLITES tables in the database. In order to resolve this, run the following commands on ...
    • Error No: 00621 appears when trying to log into SMARTEAM.

      Error No: 00621 appears when trying to log into SMARTEAM. Error No: 00621 The security device option ('Editor') does not match the database. You might be exceeding the number of licenses. Please consult with your System Administrator. This error ...
    • Error No 00067 appears when logging into SMARTEAM Editor.

      Error No 00067 appears when logging into SMARTEAM Editor. Error No: 00067 Internal Error. The program was unable to complete the operation due to an internal error. Please report the following details to your System Administrator: The header name ...
    • Error No 00050 appears when trying to Initiate a new Flow Process in SMARTEAM.

      Error No 00050 appears when trying to Initiate a new Flow Process in SMARTEAM. Error No: 00050 The link between objects 'Start' and '<user>' already exists in the system. In order to correct this issue first have everyone log out of SMARTEAM. Then ...